IOLAN DG / TG设备服务器是简单的串行到以太网连接应用的最佳选择。 IOLAN DG / TG以紧凑的尺寸提供经济高效的解决方案,提供灵活性和先进的TrueSerial®技术,非常适合需要通过以太网进行真正串行连接的应用。 IOLAN DG1设备服务器也可用于扩展温度范围。
Features and Benefits
TrueSerial® delivers the most authentic serial connections across Ethernet
Powerful processors for the best throughput and performance on the market
Indicators for network and serial interfaces for easy troubleshooting
Plug & Play installation utility eliminates configuration hassles for all IOLANs on you IP network
TruePort software provides true remote serial ports over an Ethernet LAN
Share a serial port with multiple TCP or UDP servers
Software Development Kit available to develop powerful custom applications
Power over serial cable models eliminate costs of a separate power installation
Next Generation IP support (IPv6) for investment protection and network compatibility
Compact and protective solid steel enclosure for tabletop, wall mount or DIN rail mounting
Flexible and Reliable Serial to Ethernet Connections
The IOLAN DG/TG is ideal for connecting serial-based COM port, UDP or TCP socket based applications to remote devices. Perle’s TruePort re-director provides fixed TTY or COM ports to server based applications enabling communication with remote devices connected to Perle device servers. You can also tunnel serial data between devices across an IP network.
Easy to set up and manage, the IOLAN has a software selectable RS-232/422/485 interface capability which simplifies setup and eliminates mechanical tampering associated with DIP switch based products.
Perle’s Device Management software, shipped as standard with the IOLAN DG/TG, provides better centralised control and management of multiple units resulting in maximum uptime for your remote equipment. Protection against electrostatic discharges and power surges is provided on the IOLAN DG/TG with its robust 15Kv ESD protection circuitry enabling organizations to utilize this solution with confidence.
IOLAN Plug-ins
Backed with the experience of connecting hundreds of thousands of different devices to Ethernet over the years, using a Perle Device Server you can rest assured that virtually any device with a serial COM port will operate in conjunction with your desired application exactly as it did when you had it directly connected. If the unlikely event occurs that the Perle Device Server does not enable this out of the box, Perle will make it work.
Perle IOLAN Device Servers utilize customer installable “Device Plug-ins” to successfully network devices where other solutions have failed. Request a free engineering consultation now.
Advanced IP Technology
With support for Next Generation IP (IPv6) the IOLAN range provides organizations with investment protection to meet this rapidly growing standard.
Demand for IPv6, which is compatible with IPv4 addressing schemes, is driven by the need for more IP address. With the implementation and rollout of advanced cellular networks, a robust method is needed to handle the huge influx of new IP addressable devices on the Internet. In fact, the US Department of Defense has mandated that all equipment purchased be IPv6 compatible. In addition, all major Operating Systems such as Windows, Linux, Unix and Solaris, as well as routers, have built-in support for IPv6.
It is therefore important for end users and integrators to select networking equipment that incorporates the IPv6 standard. The IOLAN line with support for IPv6 already built in, is the best choice in serial to Ethernet technology.
Lifetime Warranty
The Perle IOLAN DG/TG Device Server is backed by the best service and support in the industry including Perle’s unique lifetime warranty. Since 1976 Perle has been providing its customers with networking products that have the highest levels of performance, flexibility and quality.
特点:
Serial Port Access | |
---|---|
Connect directly using Telnet and Reverse Telnet | |
Multihost access enables multiple hosts/servers to share serial ports | |
Accessibility | |
In-band ( ethernet ) and out-of-band ( dial-up modem ) support | |
IPV6 and IPV4 addressing support | |
Availability | |
Primary/Backup host functionality enables automatic connections to alternate host(s) | |
Security | |
Local database USERID/PASSWORD | |
Disable unused daemons | |
Terminal Server | |
Telnet | |
Auto session login | |
MOTD - Message of the day | |
Serial machine to Ethernet | |
Tunnel raw serial data across Ethernet | |
Raw serial data over TCP/IP | |
Raw serial data over UDP | |
Serial data control of packetized data | |
Share serial ports with multiple hosts/servers | |
Virtual modem simulates a modem connection - assign IP address by AT phone number | |
TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX. For a complete list of all the latest drivers click here | |
"TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity" | |
RFC 2217 standard for transport of serial data and RS232 control signals | |
Customizable or fixed serial baud rates | |
Plug-ins allow customer or Perle provided plug-ins for special applications | |
Software Development Kit ( SDK ) available | |
Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101 | |
ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP | |
Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 4K bytes circular per port | |
Console Management | |
Sun / Oracle Solaris Break Safe | |
Reverse Telnet | |
OA&M ( Operations, Administration and Management ) | |
SNMP V3* - read and write, Perle MIB | |
Syslog | |
Perle Device Manager - Windows based utility for large scale deployments | |
Configurable default configuration | |
Installation Wizard | |
Set a Personalized Factory Default for your IOLANs | |
Protocols | |
IPv6, IPv4, TCP/IP, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, Telnet, raw, reverse Telnet, WINS, HTTP, SNMPV3*, RFC2217 |
硬件:
Hardware Specifications
IOLAN DG1 | IOLAN TG2 | IOLAN DS1 | IOLAN TS2 | |
---|---|---|---|---|
Processor | 600Mhz ARM Processor | MPC852T, 66 Mhz, 87 MIPS | ||
Memory | ||||
RAM MB | 512 | 16 | ||
Flash MB | 4000 | 4 | ||
Interface Ports | ||||
Number of Serial Ports | 1 | 2 | 1 | 2 |
Serial Port Interface | Software selectable RS-232/422/485 on DB25F, DB9M or RJ45 | RS-232 on RJ45 - 10 pin | Software selectable RS-232/422/485 on DB25M, DB25F, DB9M or RJ45 | RS-232 on RJ45 - 10 pin |
Sun / Solaris | Sun / Oracle ‘Solaris' Safe - no "break signal" sent during power cycle causing costly server re-boots or downtime | |||
Serial Port Speeds | 300bps to 230Kbps with customizable baud rate support | 50bps to 230Kbps with customizable baud rate support | ||
Data Bits | 5,6,7,8, 9-bit protocol support | |||
Parity | Odd, even, Mark, Space, None | |||
Flow Control | Hardware, Software, Both, None | |||
Serial Port Protection | 15Kv Electrostatic Discharge Protection ( ESD ) | |||
Local Console Port | RS232 on Serial Port | |||
Network | Autosensing 1000base-T / 100base-TX / 10base-T Auto-MDIX | 10base-T / 100base-TX ethernet RJ45 | ||
Software selectable Ethernet speed 10/100/1000 | Software selectable Ethernet speed 10/100 Auto | |||
Software selectable Half/Full/Auto duplex | ||||
Ethernet Isolation | 1.5Kv Magnetic Isolation | |||
Power | ||||
Power Supply | 120 V AC (USA), 230V AC (International) Wall Power Adaptor included | |||
Power Supply Options | Power via External power 9-30v DC, 4.8 Watts uses standard 5.5mm x 9.5mm x 2.1mm barrel socket, Power IN over serial cable. | |||
Nominal Input Voltage | 12v DC / 24v DC | |||
Input Voltage Range | 9-30v DC | |||
Power IOLAN over Serial | 9 - 30v DC with DB25 and RJ45 models | 9 - 30v DC with DB25 and RJ45 models | N/A | |
Typical Power Consumption '@ 12v DC ( Watts ) | 1.9 | 2 | 1.7 | 1.7 |
Indicators | ||||
LEDs | Power / Ready | |||
Network link | ||||
Network link activity | ||||
Serial: Transmit and Receive data per port | ||||
Environmental Specifications | ||||
Heat Output ( BTU/HR ) | 6.8 | 8.9 | 5.8 | 5.8 |
MTBF ( Hours ) | 267,483 | 254,834 | 124,004 | 299,680 |
Calculation model based on MIL-HDBK-217-FN2 @ 30 °C | ||||
Operating Temperature | 0ºC to 55ºC ( 32ºF to 131ºF ) | |||
Storage Temperature | -40ºC to 66ºC, (-40ºF to 150ºF ) | |||
Humidity | 5 to 95% (non condensing) for both storage and operation. | |||
Case | SECC Zinc plated sheet metal (1 mm) | |||
Ingress Protection Rating | IP40 | |||
Mounting | Wall or Panel mounting . DIN Rail mounting kit optional | |||
Product Weight and Dimensions | ||||
Weight | .23 KG (.51 lbs) | |||
Dimensions | 90 x 64 x 22 (mm), 3.6 x 2.5 x 0.87 (in) case dimensions not including mounting tabs, | |||
90 x 89 x 24 (mm), 3.6 x 3.5 x 0.87 (in) includes mounting tabs. | ||||
Packaging | ||||
Shipping Dimensions | 260 x 170 x 70 (mm), 10.2 x 6.7 x 2.8 (in) | |||
Shipping Weight | 0.49 KG (1.1 lbs) | |||
Regulatory Approvals | ||||
Emissions | CFR47 FCC Part 15 Subpart B:2015 | CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A | ||
ICES-003:2016 Issue 6:2016 | ICES-003, Issue 4, February 2004 (Canada) | |||
CISPR 32:2015/EN 55032:2015 (Class A) | ||||
EN55011 (CISPR11) | ||||
CISPR 16-2-3:2010/A2:2014 | ||||
EN61000-3-2:2014, Limited for Harmonic Current Emissions | EN61000-3-2 : 2010, Limits for Harmonic Current Emissions | |||
EN61000-3-3:2013, Limits of Voltage Fluctuations and Flicker | EN61000-3-3 : 2010, Limits of Voltage Fluctuations and Flicker | |||
Immunity | CISPR 24:2010/EN 55024:2010 | |||
EN61000-4-2: 2009 Electrostatic Discharge | ||||
EN61000-4-3: 2006/A2:2010: RF Electromagnetic Field Modulated | ||||
EN61000-4-4: 2004 Fast Transients | ||||
EN61000-4-5: 2006 Surge | ||||
EN61000-4-6: 2009 RF Continuous Conducted | ||||
EN61000-4-8: Power-Frequency Magnetic Field | ||||
EN61000-4-11: Voltage Dips and Voltage Interruptions | ||||
Safety | IEC 62368-1 and EN 62368-1:2014 | IEC 60950-1 (ed 2); am1 am2 and EN 60950-1:2006 +A11:2009 +A1:2010 +A12:2011 +A2:2013 | ||
CAN/CSA-C22.2 No. 62368-1-14 and UL 62368-1 | CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1, Second Edition | |||
Other | Reach, RoHS and WEEE Compliant Directive 2011/65/EU restriction of the use of certain hazardous substances in electrical and electronic equipment and meets the following standard:: EN 50581:2012 | |||
ECCN - 5A991 | ||||
HTSUS Number: 8471.80.1000 | ||||
Perle Lifetime warranty | ||||
Serial Connector Pinout | |||||
---|---|---|---|---|---|
IOLAN DB9M Socket | Direction | RS232 | RS485 Full Duplex | RS485 Half Duplex | RS422 |
1 | ![]() | DCD | - | - | - |
2 | ![]() | RxD | RxD+ | - | RxD+ |
3 | ![]() | TxD | TxD+ | DATA+ | TxD+ |
4 | ![]() | DTR | - | - | - |
5 | ![]() | GND | GND | GND | GND |
6 | ![]() | DSR | RxD- | - | RxD- |
7 | ![]() | RTS | - | - | - |
8 | ![]() | CTS | - | - | - |
9 | ![]() | - | TxD- | DATA- | TxD- |
IOLAN RJ45 Socket | Direction | RS232 | RS485 Full Duplex | RS485 Half Duplex | RS422 |
1 | ![]() | Power In | Power In | Power In | Power In |
2 | ![]() | DCD | - | - | - |
3 | ![]() | RTS | TxD+ | DATA+ | TxD+ |
4 | ![]() | DSR | - | - | - |
5 | ![]() | TxD | TxD- | DATA- | TxD- |
6 | ![]() | RxD | RxD+ | - | RxD+ |
7 | ![]() | GND | GND | GND | GND |
8 | ![]() | CTS | RxD- | - | RxD- |
9 | ![]() | DTR | - | - | - |
10 | ![]() | - | - | - | - |
IOLAN DB25M Socket | Direction | RS232 | RS485 Full Duplex | RS485 Half Duplex | RS422 |
1 | ![]() | Shield | Shield | Shield | Shield |
2 | ![]() | TxD | - | - | - |
3 | ![]() | RxD | - | - | - |
4 | ![]() | RTS | - | - | - |
5 | ![]() | CTS | - | - | - |
6 | ![]() | DSR | - | - | - |
7 | ![]() | GND | GND | GND | GND |
8 | ![]() | DCD | - | - | - |
9 | ![]() | - | - | - | - |
12 | ![]() | Power In | Power In | Power In | Power In |
13 | ![]() | - | - | - | CTS- |
14 | ![]() | - | TxD+ | DATA+ | TxD+ |
15 | ![]() | - | TxD- | DATA- | TxD- |
18 | ![]() | - | - | - | RTS+ |
19 | ![]() | - | - | - | RTS- |
20 | ![]() | DTR | - | - | - |
21 | ![]() | - | RxD+ | - | RxD+ |
22 | ![]() | - | RxD- | - | RxD- |
25 | ![]() | - | - | - | CTS+ |
IOLAN DB25F Socket | Direction | RS232 | RS485 Full Duplex | RS485 Half Duplex | RS422 |
1 | ![]() | Shield | Shield | Shield | Shield |
2 | ![]() | RxD | - | - | - |
3 | ![]() | TxD | - | - | - |
4 | ![]() | CTS | - | - | - |
5 | ![]() | RTS | - | - | - |
6 | ![]() | DTR | - | - | - |
7 | ![]() | GND | GND | GND | GND |
8 | ![]() | DCD | - | - | - |
9 | ![]() | - | - | - | - |
12 | ![]() | Power In | Power In | Power In | Power In |
13 | ![]() | - | - | - | RTS- |
14 | ![]() | - | RxD+ | - | RxD+ |
15 | ![]() | - | RxD- | - | RxD- |
18 | ![]() | - | - | - | CTS+ |
19 | ![]() | - | - | - | CTS- |
20 | ![]() | DSR | - | - | - |
21 | ![]() | - | TxD+ | DATA+ | TxD+ |
22 | ![]() | - | TxD- | DATA- | TxD- |
25 | ![]() | - | - | - | RTS+ |
Optional Perle adapters for use with straight thru CAT5 cabling |
选型: